News
News

Partastar 51.2V 280Ah Energy Storage Product - Brand Messaging & Titles

2026-02-10 GUANGDONG PARTASTAR NEW ENERGY CO., LTD. 0
Category Parameter Specification Test Condition/Standard
Basic Electrical Parameters Nominal Voltage 51.2 V -
Rated Capacity 280 Ah (≈14.34 kWh) 0.5C discharge @25°C to cut-off voltage  
Nominal Energy 14.34 kWh Calculated (51.2V × 280Ah)  
Operating Voltage Range 44.8 V - 58.4 V Corresponding to 2.8V - 3.65V per cell  
Recommended Working Range 48 V - 57.6 V (SOC 20%-100%) For optimal cycle life  
Standard Charge Current 140 A (0.5C) Constant Current-Constant Voltage (CC-CV)  
Maximum Continuous Charge Current 280 A (1C) With active cooling @25°C  
Standard Discharge Current 140 A (0.5C) -  
Maximum Continuous Discharge Current 280 A (1C) With active cooling @25°C  
Peak Discharge Current (10 sec) 560 A (2C) ≤40°C cell temperature  
Internal Resistance (Pack) ≤25 mΩ @50% SOC, 1kHz AC impedance  
Cycle Life & Durability Cycle Life @80% DoD ≥6,000 cycles To 80% initial capacity, 0.5C/0.5C @25°C
Cycle Life @100% DoD ≥3,500 cycles To 80% initial capacity, 0.5C/0.5C @25°C  
Calendar Life ≥10 years @25°C, 50% SOC storage  
Energy Efficiency (Round-trip) ≥95% 0.5C charge/discharge, excluding BMS  
Self-Discharge Rate ≤3% per month @25°C, 50% SOC  
Mechanical & Environmental Specifications Cell Configuration 16S1P (16 cells in series) -
Cell Type Prismatic LiFePO₄, 3.2V/280Ah -  
Dimensions (L×W×H) 442 × 420 × 218 mm (standard rack) -  
Weight Approx. 142 kg -  
Ingress Protection (IP) IP20 (indoor use) -  
Operating Temperature (Charge) 0°C to 55°C (32°F to 131°F) -  
Operating Temperature (Discharge) -20°C to 60°C (-4°F to 140°F) -  
Storage Temperature -10°C to 45°C (14°F to 113°F) -  
Relative Humidity 5% - 95% (non-condensing) -  
Cooling Method Passive / Natural convection (forced air optional) -  
Communication Interface CAN 2.0B / RS485 / RS232 -  
Protection Functions Over/Under Voltage, Over Current, Short Circuit, High/Low Temperature, Cell Balancing -  
Charge Profile (CC-CV) Constant Current (CC) Stage 140A (0.5C) Until pack voltage reaches 58.4V
Constant Voltage (CV) Stage 58.4V ± 0.2V Until current drops to ≤14A (0.05C)  
Total Charge Time ~2.5 hours (0%-100% SOC) @0.5C, at 25°C  
System Integration Data Recommended Inverter Voltage Range 45V - 60V DC input -
BMS Type Active balancing, ≥500mA balance current -  
Installation Orientation Vertical (preferred) or horizontal -  
Mounting 19" standard rack mount (2U height) -  
Terminal Type M8 bolt (torque: 12-15 N·m) -  
Communication Protocol Modbus RTU (standard), CAN bus (optional) -  
Certifications UN38.3, CE, RoHS (UL 1973 pending) -  

Online Message

Contact
google-site-verification=U9ZPasEGCDdnzPZmyIxDlPEDHXQnCkFRm1-GSqSEJEA